SCIF doors must be solid wood core or a specially constructed door filled with sound attenuation material of STC 45 rating or higher. 4. Elements of a SCIF(cont’d) Physical SCIF Perimeter. that store or process classified information. Door Construction Types: Selections of entrance and emergency exit doors shall be consistent with SCIF perimeter wall construction. 3. SCIF Construction Overview of SCIF Palmer’s Contracting Group is a leading design-build construction firm specializing in SCIF (Sensitive Compartmentalized Information Facilities). copper and ¼” flake board. This website uses cookies to improve your experience while you navigate through the website. Depending on the extent of your security in depth, your accrediting official will require you to have either plywood in the walls or expanded metal, which looks like a large diamond mesh. For each SCIF construction project, a Construction Security Plan (CSP) shall be developed to address the application of security to the SCIF planning, design, and construction efforts. Jaye Andone is president and CEO of SCIF Global Technologies. The walls between the SCIF areas and non-SCIF areas must have a 2-hour firewall rating. This category only includes cookies that ensures basic functionalities and security features of the website. In most cases, SCIF perimeter construction and acoustic protection should provide the necessary protection for Sound Group 3. The perimeter of the facility must meet a rating of STC (Sound Transmission Class) 45 at a minimum, or STC 50 if you’ll be using amplified sound, such as video teleconferencing, speaker phone or a PA system. Wall, floor, ceiling/roof construction. Each detail is available in PDF and AutoCAD (DWG) formats, go to our secure FTP site (do NOT use Internet Explorer, use another browser) for the DWG format drawings.. Per the UFC 4-010-05, 3-5.8.2 - "Sprinkler pipe shall be provided with a UL Listed dielectric union inside the SCIF perimeter adjacent to the penetration, or ground the pipe within 6" of the perimeter penetration using a no. Professay discount code 3 . They also depend on the existing SID, whether the facility is going to be open or closed storage and other considerations as identified by the accreditation official. 4.1 Vault Construction Criteria 4.2 SCIF Criteria For Permanent Dry Wall Construction 4.3 SCIF Construction Criteria For Steel Plate 4.4 SCIF Construction Criteria For Expanded Metal 4.5 General GLOSSARY PREFACE: DCID 1/21, Physical Security Standards for Sensitive Compartmented Information Facilities copper and ¼” flake board. SENSITIVE COMPARTMENTED INFORMATION FACILITIES PLANNING, DESIGN, AND CONSTRUCTION CANCELLED. We are aggressively working on updating the hundreds of Cold-Formed Framing Details located in the CAD Library with updated product information. We have expertise in building sensitive compartmented information facilities (SCIFs), Special Access Program Facilities (SAPFs), and Department of Defense Closed Areas. That said, there are a lot of components that go into getting that job done. SPG is a turnkey provider with a whole suite of services ranging from accreditation assistance, ICD 705 compliance, testing and validation, and even manufacturing. UFC 4-010-05 1 February 2013 . RF Shielding. TEMPEST refers to protecting the electromagnetic emanations coming off of processing equipment (laptops, servers, etc.) Community Standard (ICS) 705-1 (Physical and Technical Standards for Sensitive Compartmented Information Facilities). Zurich diagnostics zr11 master manual 4 . In addition to the manbars at the wall penetration, a 1.5-hour fire damper is needed for all duct penetrations. Vault – concrete or steel construction. Based in central Florida, we have worked with federal agencies on projects ranging from SCIF construction to modular military barracks, fortified equipment shelters, courthouses, justice centers, administrative facilities, government office complexes, and more. 'In D.C., everyone talks SCIF, SCIF, SCIF,' said Bruce Paquin, who moved to Florida from the Washington region several years ago to start a SCIF construction business. We'll assume you're ok with this, but you can opt-out. this information may not contain all details required for construction. The SCIF fits within most offices and dwellings. All A.R.C. SCIF. The emanations are unintentional, but they allow the possibility of the information being intercepted and exploited. As part of the specifications, there must be a dielectric break when penetrating the wall (this helps break up … Penetrations of the SCIF Perimeter. Sensitive Compartmented Information Facilities (SCIFs), also referred to as security rooms, are secure, acoustic rooms designed to protect sensitive information. Community Standard (ICS) 705-1 (Physical and Technical Standards for Sensitive Compartmented Information Facilities). CANCELLED. Your email address will not be published. Navigating through these requirements can be intimidating and challenging, so it’s important to have expertise within your team. The specific format and content of the CSP may be developed by the AO based upon the extent of the SCIF construction and security concerns related to the SCIF. ... Table C-1 Minimum SCIF Wall Construction and Alarm..... 45. Ipad keyboard case with trackpad 2 . VA Standard Details numbering system relates to specification MasterFormat 2004. That’s why it’s important to understand how to build a SCIF correctly from the beginning. identity of all system components installed within the SCIF. This website uses cookies to improve your experience. These cookies do not store any personal information. With all the above methods of design and construction, acoustical attenuation must be dealt with and designed in. Whether used by the military or by civilian contractors, SCIFs are designed from the ground up to safeguard the nation’s most sensitive information. Certified Shielded Enclosure (CSE) – SCIF. Developed by TinyFrog. The openings, the duct work and the duct breaks must also have non-metallic inserts to secure the sounds emitted within the SCIF. Sensitive Compartmented Information Facilities (SCIFs), also referred to as security rooms, are secure, acoustic rooms designed to protect sensitive information. This requires steel or wood studs, offset mounted away from the SCIF walls. LANL Standard Drawings and Details either (1) depict required format/content or (2) are templates that are completed by a Design Agency (LANL or external AE) for a design drawing package, in a manner similar to specifications. Lakeside, CA 92040, Privacy Policy - Terms of Service - © 2020 All rights reserved. The Primary purpose of this design guide is to provide details on sound rated assemblies; where the Fire Design Guide is rightly focused on the fire resistance rating. In the case of retrofitting an existing room to SCIF specifications, even wood fillers must meet sound suppression requirements. A security wall (under standard ICD/ICS 705) details the technical specifications for a SCIF wall (sensitive compartmented information facility). PCG has built numerous SCIF spaces for private sector firms and the intelligence community. The bars must be welded in place five inches on center. Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. In addition to the manbars at the wall penetration, a 1.5-hour fire damper is needed for all duct penetrations. The specific format and content of the CSP may be developed by the AO based upon the extent of the SCIF construction and security concerns related to the SCIF. If you already have a concrete wall, that will satisfy the physical hardening requirement. The copper hangs over the flake board at two edges However, when Sound Group 3 or 4 can’t be met within the normal SCIF construction standards, there are supplemental mitigations used … Sound sealing door gaskets and door sets must also be rated at a minimum of STC45. Hot, Crowded And Secret Room Now Part Of Impeachment Lore. The threshold must be fitted to the automatic door bottom for positive seal. In most cases, SCIF perimeter construction and acoustic protection should provide the necessary protection for Sound Group 3. Request a Quote or give her a call: 904-524-0911, Your email address will not be published. The purpose of hardening is to first prevent overall access to unauthorized personnel and secondly protect the space from forced entry, and there are a few acceptable means. Radio frequency (RF) shielding may require RF foil or RF paint to be added to the walls. National was founded by industry specialists with over 50 years of combined experience in the RF shielding industry. APPROPRIATE MODIFICATION MAY BE REQUIRED TO ENSURE SUITABILITY OF THESE DRAWINGS FOR THE SPECIFIC APPLICATION. Community recorder northern ky 5 . The facility is required to be designed and built according to the current version of the Intelligence Community Directive (ICD) 705 and per the referenced “Technical Specifications for Construction and Management of Sensitive Compartmented Information Facilities” (or “Tech Spec,” which you can find. Updated ClarkDietrich Building System CAD Details can be found in the new ClarkDietrich's iTools CAD Library. An overview of what’s required for the construction of a Sensitive Compartmented Information Facility (SCIF). UFC 4-010-05 1 February 2013 . But opting out of some of these cookies may have an effect on your browsing experience. Phone: 562-695-0645 Fax: 562-692-0146 4880 Gregg Road Pico Rivera, CA 90660 All of our modular construction projects are built to the Vaults have continuously welded seams and are manufactured of robust ¼” steel. Start studying ICD 705 -Technical Specifications v1.2 CH 3 and 4. Contact ClarkDietrich Technical Services at (888) 437-3244 for any questions on these details, or if you The manufacturer recommends cutting the SCIF barrier 12" longer than the length of the wall, ceiling or floor to be covered to allow SCIF Barrier to wrap around corners. Inherent RF Shielding. The SCIF fits within most offices and dwellings. ICD 705 Construction Company USA Retrofit Modular SCIF "Hide In Sight" Custom Sensitive What Is A SCIF? An STC 45-rated door bottom must be either routed in the door bottom or installed on the door face. This handbook contains security procedures, and details for the construction of Sensitive Compartmented Information Facilities (SCIF) for the Department of Homeland Security (DHS). SCIF Global Technologies is proud to be a Sustaining Member of SAME, the Society of American Military Engineers and ASIS International. Sensitive Compartmented Information Facilities, Technical Specifications for Construction and Management of Sensitive Compartmented Information Facilities, Version 1.2. The panels are attached to wood framing placed on 16” on center. The IDS includes protections for the perimeter doors, interior motion sensors and other devices that report to a monitored premise control unit (PCU). Inherent RF Shielding. Compare Search ( Please select at least 2 keywords ) Most Searched Keywords. Whether for military, law enforcement, or commercial purposes, SCIF walls, ceilings, and floors are acoustically treated to keep sound from leaking into the surrounding environment. 4. Sensitive Compartmented Information Facility (pronounced “skiff”), a U.S. Department of Defense term for a secure room.It can be a secure room or data center that guards against electronic surveillance and suppresses data leakage of sensitive security and military information. We’re GSA licensed, and are the chosen provider of Sound Masking systems by a number of government organizations and businesses. These cookies will be stored in your browser only with your consent. 11980 Woodside Ave, Suite 1 RF Ceiling and Wall Construction The ceiling and walls of Nelco’s copper RF shielded enclosure are built using 3’ x 8’ panels consisting of 5 oz. Keep in mind that the floors and ceilings must also have physical protection equal to the walls. Professay discount code 3 . When faced with the construction of a SCIF or Secure Room the best approach is to either retain a SCIF Specialty Contractor or a SCIF Consultant. iv . "SCIF size has become a measure of status in Top Secret America, or at least in the Washington region of it. a. Affordable Structures offers modular SCIF building floor plans in a variety of custom configurations. PCG has subject matter experts on hand to include ICD 705 requirements. E213164 js165a ballast 1 . If No, skip to 5 Yes No. UFC 4-010-05 1 February 2013 Change 1, 1 October 2013 ... Table C-1 Minimum SCIF Wall Construction and Alarm..... 49. Are there any Radio Transmitters or Receivers located in the SCIF or within three meters of the SCIF’s perimeter wall? When we talk about Sensitive Compartmented Information Facilities, commonly called SCIFs, we are talking about a high security facility designed to secure information and communications. Necessary cookies are absolutely essential for the website to function properly. You also have the option to opt-out of these cookies. If applicable, indicate where they leave the SCI area, where the antenna is and show the locations of all Isolators and filters. All A.R.C. Limited number of locations for perimeter penetrations When the SCIF is unoccupied, it must be protected by an intrusion detection system (IDS), which has to meet the UL-2050 specification for protecting national security information. We have described the systems based on the sound test, which in many cases, is different than the manner in which the assembly may have been built for the fire test. The SCIF fits within most offices and dwellings. However, the materials used to secure these facilities won’t be found in Home Depot. No detail is too small when it comes to keeping secret information secret. A security wall (under standard ICD/ICS 705) details the technical specifications for a SCIF wall (sensitive compartmented information facility). Learn vocabulary, terms, and more with flashcards, games, and other study tools. Door and door hardware. 2. VA Standard Details numbering system relates to specification MasterFormat 2004. This type of construction method is more obvious to outsiders as to what you are doing, the attenuation levels to which you wish to attain, and why. Are there any Radio Transmitters or Receivers located in the SCIF or within three meters of the SCIF’s perimeter wall? If you don’t already have a concrete wall to use, you’ll construct a wall assembly, which must include 16-gauge metal studs spaced a maximum of 16 inches on center. An STC 45-rated door bottom must be either routed in the door bottom or installed on the door face. PCG has built numerous SCIF spaces for private sector firms and the intelligence community. 'They've got the penis envy thing going. Community recorder northern ky 5 . If the facility will be electronically processing classified information, it will require TEMPEST mitigations. Download thousands of free detailed design & planning documents including 2D CAD drawings, 3D models, BIM files, and three-part specifications in one place E213164 js165a ballast 1 . To design and construct a SCIF, there are certifications (or accreditations) that must be obtained to confirm that the SCIF meets industry and legal standards. A modular SCIF includes a frame made from a plurality of prefabricated channels, and a plurality of prefabricated wall and ceiling panels that are attached to the frame. And without a government sponsor or input, you’ll have a room that’s acoustically, physically and electronically protected like a SCIF, but you can’t call it a SCIF or store or process classified information within the facility. a. However, when Sound Group 3 or 4 can’t be met within the normal SCIF construction standards, there are supplemental mitigations used … Details Brochure Ducts are not the only equipment that need manbar protection through the SCIF perimeter wall. In order for a facility to be accredited by the government as a SCIF (Sensitive Compartmented Information Facility) or SAPF (Special Access Program Facility), two key items are required: Without following the Tech Spec during planning, design and construction, the government is not obligated (and likely won’t) accredit the facility. identity of all system components installed within the SCIF. Depending on the extent of your security in depth , your accrediting official will require you to have either plywood in the walls or expanded metal, which looks like a large diamond mesh. The details of your design depend on whether the SCIF is going to be ground-up construction or part of an existing building. A modular SCIF includes a frame made from a plurality of prefabricated channels, and a plurality of prefabricated wall and ceiling panels that are attached to the frame. Certified Shielded Enclosure (CSE) – SCIF. For each SCIF construction project, a Construction Security Plan (CSP) shall be developed to address the application of security to the SCIF planning, design, and construction efforts. … This handbook provides key milestones, construction standards, electrical and technical guidance for use when planning and executing the construction Required fields are marked *, ModularContainerTEMPESTMobile Command CenterConsultingFFC AssistanceSite VisitsProject ManagementFinancing/Leasing OptionsOther Products/Services. To that end, no amount of time, effort, or technology would be construed as excessive. Below is a 30,000-foot view of the current ICD 705 standards, but keep in mind that every SCIF project will come with its own set of challenges and unique requirements based on the government’s input and guidance throughout the process. This type of construction method is more obvious to outsiders as to what you are doing, the attenuation levels to which you wish to attain, and why. The openings, the duct work and the duct breaks must also have non-metallic inserts to secure the sounds emitted within the SCIF. Whether the SCIF is a secure room within a facility or is a portable unit designed to be shipped to any part of the globe, the job is still the same. Ipad keyboard case with trackpad 2 . These doors mean business. There are four main differences between SCIF construction and standard construction, which all protect the perimeter. SCIF doors must be solid wood core or a specially constructed door filled with sound attenuation material of STC 45 rating or higher. CANCELLED. A government rule called "The Director of Central Intelligence Directive 6/9" details the physical requirements for SCIF construction: Walls, floor … Sensitive Compartmented Information Facilities,” September 17, 2010 (h) Intelligence Community Standard 705-2, “Standards for the Accreditation and Reciprocal ... SCIF construction overseas shall also comply with applicable local anti-terrorism and force protection regulations. The copper hangs over the flake board at two edges Do I need a SCIF or Secure Room Consultant? The modular SCIF includes a prefabricated door and doorframe that are attached to the modular SCIF. If you don’t already have a concrete wall to use, you’ll construct a wall assembly, which must include 16-gauge metal studs spaced a maximum of 16 inches on center. In addition to securing the SCIF from physical entry, the doors must also contain sound within the room. Everything from construction materials to access controls and detection/alarm systems is built to government specifications using the latest technology as mandated by the DOD. As part of the specifications, there must be a dielectric break when penetrating the wall (this helps break up … SPG is a SCIF construction company provides an entire suite of services addressing all of your Secure Facilities requirements. Vaults have continuously welded seams and are manufactured of robust ¼” steel. You can either take a SCIF development class so that you yourself understand the entire process, or bring in an expert to work with your team to make sure the process is as efficient as possible. LANL Standard Drawings and Details either (1) depict required format/content or (2) are templates that are completed by a Design Agency (LANL or external AE) for a design drawing package, in a manner similar to specifications. 3. PCG has subject matter experts on hand to include ICD 705 requirements. Addeddate 2014-11-20 19:00:19 Identifier pdfy-kMb7hA88htSa3qte Identifier-ark ark:/13960/t2p58k086 Ocr ABBYY FineReader 9.0 Ppi 300 Scanner Internet Archive Python library 0.6.3 Inside The Room Used For Intelligence 12 Best SCIF Images On Pinterest. When the technical specifications herein are applied to new construction and renovations of Sensitive Compartmented Information Facilities (SCIFs), they shall satisfy the standards outlined in ICS 705-1 to enable uniform and Designs are not limited to the pictures shown below. My geek essay 6 . When faced with the construction of a SCIF or Secure Room the best approach is to either retain a SCIF Specialty Contractor or a SCIF Consultant. 4 wire to the building ground." Scif wall construction details. Sound transmission coefficient (STC) Rating of 45 or 50. 4 wire to the building ground." The panels are attached to wood framing placed on 16” on center. Do I need a SCIF or Secure Room Consultant? To design and construct a SCIF, there are certifications (or accreditations) that must be obtained to confirm that the SCIF meets industry and legal standards. Copyright © 2013 - 2017 SCIF Global Technologies, Inc. • 904-265-1902. SCIF Constructors takes pride in our ability to understand government security needs and translate them into cost-effective, commercial construction designs. SENSITIVE COMPARTMENTED INFORMATION FACILITIES PLANNING, DESIGN, AND CONSTRUCTION.